Measuring bioburden for cleaning validation protocols

A Matrix of Equipment combination with the details of equipment name, I.

The critical parts of equipment, which are difficult to clean, shall be considered for sampling. Sodium lauryl sulphate SF: Sampled swab area cm2 TS: The first step of the sampling sequence is the test for microbiological contamination to prevent false positive results from preceding tests.

Single therapeutic dose smallest strength based on number of mg of active ingredient of previous product Product A SF: The last step of the sampling sequence is the rinse sampling. Sampling shall be done from all the pre-decided locations and as per surface area mentioned.

On the basis of dose criteria and 10 ppm criteria the MACO limit shall be calculated and the dose criteria limit shall be selected as a Worst Case condition.

Batch size of the next product in mg. Dose Criteria or safety based criteria or medical limit criteria As per this criteria not more 0. The Worst Case is considered on the basis of following factors: The second step of the sampling sequence is the swab test.

For cleaned equipment hold time studies the cleaned equipments must be kept completely closed covered with cling film. After satisfactory observation, the equipment shall be allowed for sampling.

Rationale for the residue limit established should be scientific, logical and based upon knowledge of the material. LD50 value lethal dose of the cleaning agent i. Cleaning Validation Approach This specific protocol shall be applicable to Tablet and Capsule section only.

Cleaning Validation Protocol

The limits should be practical, achievable and verifiable. Maximum Daily Dose; milligram of dosage units of the product B taken per day 10 ppm criteria As per this criterion, not more than 10 ppm of any product will appear in another product.

A successful visual inspection is a pre requisite for sampling.

Safety Factor BS: Batch size of the next product product B i. Solubility, Cleanability Therapeutic Dose of the Product Concentration of Active Ingredient Equipment combination Equipment Train In this bracketing approach cleaning validation of each equipment train shall be performed based upon the worst-case product selected for that equipment train.

Visual inspection shall be performed after completion of cleaning and drying of equipments. If the cleaning is not done in the same area.

Cleaning Agent Residue Contamination The rationale for selecting limits of carryover of cleaning agent sodium lauryl sulphate residue shall be logically based on the material involved.

Worst case is those conditions within normal parameters most likely to give failure. Critical in-process control shall be evaluated with respect to the laid down specification.

Lacs This is an Indian system of counting and 10 lacs is equal to 1 million. The following equation is used to calculate the limit of product A if the next product on the production schedule is product B.For bioburden recovery in cleaning validation studies, the focus is on recovery of mesophilic aerobic microbes.

For this purpose, TSA medium incubated at 30–35°C is suitable. However, alternate media and incubation conditions may be required if the detection of a specified microbial species is a concern.

Measuring Bioburden in Protocols: More on Using Rinse Sampling Alone: Separating CEHT Protocols from Cleaning Protocols: Mock soiling - A process of soiling the equipment for a cleaning validation protocol in which soil is applied to the equipment surfaces to simulate the condition of the soil on those surfaces following typical product.

Guidance on cleaning validation did not consider microbial issues at first – FDAs guidance* was limited to “equipment cleaning for chemical residues only”. criterion for the cleaning validation protocol and the baseline data for the CEHT study.

Admittedly, if the CEHT study is done separately from the cleaning validation protocol, this may not be an advantage.

For aseptic processing, the objection can be made that the equipment is subsequently sterilized, so measuring bioburden is not necessary. Nov 25,  · guide to inspections validation of cleaning processes Note: This document is reference material for investigators and other FDA personnel.

The document does not bind FDA, and does no confer any rights, privileges, benefits, or immunities for or on any person(s). Measuring Bioburden for Cleaning Validation Protocols Research Paper Measuring Bioburden for Cleaning Validation Protocols Destin A. LeBlanc Cleaning Validation Technologies [email protected] November .